If the high forward reach is over an obstruction reach and clearances shall be as shown in here under.
Maximum size of ada door handle obstruction.
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches 455 mm of the latch side of a doorway projects more than 8 inches 205 mm beyond the face of the door measured perpendicular to the face of the door or gate.
Handles pulls panic bars.
Operable parts shall be operable with one hand and shall not require tight grasping pinching or twisting of the wrist.
Door opening space from the face of the door up to stop of the door frame must be between 32 inches minimum to a 48 inches maximum.
Door pressure gauges and other products are available to measure the opening force.
Fire resistance rated glazing tested to astm e 119 or ul 263 and nfpa 252 ul 10b or ul 10c shall be permitted in fire door assemblies located in fire walls and in fire barriers in accordance with table 716 5 to the maximum size tested and in accordance with their listings.
Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
Minimum of 18 inches minimum between the latch side and any obstruction a wall columns objects etc for a forward approach to the door.
Such devices like other door and gate hardware must operate with a maximum 5 lbf force 404 2 7 but their operating force is not included in the measure of door or gate opening force.
Section 404 of the ada states.
Each fire door including its frame and hardware must be listed or approved by a nationally recognized testing laboratory.
Size min 3 0 wide 32 clear when 90 open and 6 8 in height.
Effort to operate doors 8 5 pounds at exterior doors and 5 pounds at interior doors door hardware height 30 44 above floor.
Door hardware operable with a single effort without requiring ability to grasp hardware.
The size of the building.
That said the hardware and direction handles latches and which way the door opens can get a bit confusing.
Toilet compartment doors including door hardware shall comply with 404 except that if the approach is to the latch side of the compartment door clearance between the door side of the compartment and any obstruction shall be 42 inches 1065 mm minimum.
In general the requirements are a minimum of 32 in width and a maximum of 48 and the door must open to 90 degrees.
The width of an exit route must be sufficient to accommodate the maximum permitted occupant load of each floor served by the exit route.